Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06 101
14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13233
C13234
Parameter | Name:
C13233 | Mapping entries RPDO-3
Data type: UNSIGNED_64
Index: 11342 = 0x2C4E
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 3.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C13233/1 0 1. Mapping entry RPDO-3 (I-1602.01)
... ... ...
C13233/32 0 32. Mapping entry RPDO-3 (I-1602.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13234 | Mapping entries RPDO-4
Data type: UNSIGNED_64
Index: 11341 = 0x2C4D
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the RPDO channel 4.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
The master must have the same mapping entries as the slave.
Structure of the mapping codes
( 66)
Value is bit-coded: Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes Lenze setting Info
C13234/1 0 1. Mapping entry RPDO-4 (I-1603.01)
... 0 ...
C13234/32 0 32. Mapping entry RPDO-4 (I-1603.20)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT