5 Installation
5.2 Electrical installation
28
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Colour code of the Ethernet cable
[5-8] Ethernet plug in accordance with EIA/TIA 568A/568B
Note!
Wiring and colour code are standardised in EIA/TIA 568A/568B.
In accordance with the industrial standard, the use of 4-pin Ethernet cables is
permissible. The cable type only connects the assigned pins 1, 2, 3 and 6 to one another.
E94YCEI004A
Pair Pin Signal EIA/TIA 568A EIA/TIA 568B
3 1 Tx + White / Green White / Orange
2 Tx - Green orange
2 3 Rx + White / Orange White / Green
1 4 blue blue
5 White / Blue Blue / White
2 6 Rx - orange Green
4 7 White / Brown White / Brown
8brown brown