EasyManua.ls Logo

Lenze ECSES Series - Page 102

Lenze ECSES Series
200 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
Power terminals
Connection to the DC bus (+U
G
, −U
G
)
5
102
EDKCSEX064 DE/EN/FR 6.0
Replacing defective fuses
Danger!
Hazardous electrical voltage
Components can carry hazardous voltages up to 3 minutes after
power−off.
Possible consequences:
ƒ Death or severe injuries when touching the device.
Protective measures:
ƒ Replace fuses in the deenergised state only.
Set controller inhibit (CINH) for all axis modules in DC−bus
operation and disconnect all power supply modules from the
mains.

Table of Contents

Other manuals for Lenze ECSES Series

Related product manuals