  • R
    Ryan MartinezAug 4, 2025
    What to do if my Lenze EPM-H502 Control Unit shows 'COM BROK' error?
    • H
      hcolonAug 4, 2025
      If the Lenze Control Unit displays a 'COM BROK' error, it indicates that the serial data cable connecting the operating unit and the PC might be defective or not properly connected. First, check the Sub-D connector to ensure it's correctly connected and firmly seated. If the problem persists, replace the serial data cable.
  • J
    Jason MaynardAug 14, 2025
    How to fix 'PR ERROR' on Lenze EPM-H502?
    • S
      Stephen WrightAug 15, 2025
      If your Lenze Control Unit shows a 'PR ERROR', it means the connection between the operating unit and the PC is faulty. Make sure the connections are firmly seated and check the cable for any damages.
  • J
    Joshua Nichols PhDAug 25, 2025
    Why does my Lenze Control Unit display 'ASIC ko1' error?
    • B
      Brett LeeAug 26, 2025
      The 'ASIC ko1' error on a Lenze Control Unit indicates either faulty wiring of the system bus or incorrect parameterization of the interface. To resolve this, check the wiring of the system bus (CAN) and verify the parameter settings, including baud rate, address, and identifier.

Summary

Document history

1 Preface and general information

2 Technical data

2.1 General data and operating conditions

Provides general specifications, conformity approvals, protection, and environmental operating conditions.

2.2 Electrical data

Details electrical specifications including display, connections, network, memory, and interfaces.

3 Mechanical installation

4 Electrical installation

4.1 Supply voltage connection

Details how to connect the DC supply voltage to the operating unit safely.

4.2 Wiring of the system bus (CAN)

Explains the principle structure and connection for the system bus (CAN).

5 Commissioning

5.2 Project transfer to the operating unit

Outlines the process for transferring a project from a PC to the operating unit.

6 Operation

6.2 Data input

Provides step-by-step examples for entering and modifying data on the operating unit.

7 Troubleshooting and fault elimination

7.1 Fault messages

Lists common fault messages, their causes, and recommended remedies.

Lenze EPM-H502 Specifications

General IconGeneral
BrandLenze
ModelEPM-H502
CategoryControl Unit
LanguageEnglish