Technical Data
821XKlimaBA0399 3-3
120 % overload 8214821382128211Type
EVF8214-E-
V020
EVF8213-E-
V020
EVF8212-E-
V020
EVF8211-E-
V020
Order no.
Motor voltage
3)
V
M
[V] 0-3
V
mains
/0Hz
¡
50Hz, if required up to480Hz
Power loss (Operation with I
Nx
) P
v
[W] 65 75 100 100
Power derating [%/K]
[%/m]
40
C<T
amb
<50
C: 2.5%/K
1000 m a.m.s.l
h
$
4000 m a.m.s.l: 5%/1000m
Field
Resolution absolute 0.02 Hz
frequency
Digital setpoint
selection
Accuracy
á
0.05 Hz
Analog setpoint
Linearity
á
0.5 %(max. selected signal level: 5 V or 10 V)
selection
Temperature
sensitivity
0
¡
40
C: +0.4 %
Offset
á
0%
Weight m[kg] 2.2 2.2 2.2 2.2
1)
This power can be additionallyobtained when operating a matching motor
2)
The currents applyto a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with75%I
Nx
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
* No dynamic chopper-frequency lowering of the inverter