Configuration
7-308

SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
210 DXRA071-12-50
211 DXRA071-22-50
212 DXRA080-12-50
214 DXRA090-12-50
215 DXRA090-32-50
216 DXRA100-22-50
217 DXRA100-32-50
218 DXRA112-12-50
219 DXRA132-12-50
220 DXRA132-22-50
221 DXRA160-12-50
222 DXRA160-22-50
223 DXRA180-12-50
224 DXRA180-22-50
DXRAXX071-12, f
d
: 50Hz
DXRAXX071-22, f
d
: 50Hz
DXRAXX080-12, f
d
: 50Hz
DXRAXX090-12, f
d
: 50Hz
DXRAXX090-32, f
d
: 50Hz
DXRAXX100-22, f
d
: 50Hz
DXRAXX100-32, f
d
: 50Hz
DXRAXX112-12, f
d
: 50Hz
DXRAXX132-12, f
d
: 50Hz
DXRAXX132-22, f
d
: 50Hz
DXRAXX160-12, f
d
: 50Hz
DXRAXX160-22, f
d
: 50Hz
DXRAXX180-12, f
d
: 50Hz
DXRAXX180-22, f
d
: 50Hz
Lenze inverter motor in delta connection
l
The temperature monitoring via resolver or encoder cable is automatically deactivated, i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
250 DXRA071-12-87
251 DXRA071-22-87
252 DXRA080-12-87
254 DXRA090-12-87
255 DXRA090-32-87
256 DXRA100-22-87
257 DXRA100-32-87
258 DXRA112-12-87
259 DXRA132-12-87
260 DXRA132-22-87
261 DXRA160-12-87
262 DXRA160-22-87
263 DXRA180-12-87
264 DXRA180-22-87
DXRAXX071-12, f
d
: 87Hz
DXRAXX071-22, f
d
: 87Hz
DXRAXX080-12, f
d
: 87Hz
DXRAXX090-12, f
d
: 87Hz
DXRAXX090-32, f
d
: 87Hz
DXRAXX100-22, f
d
: 87Hz
DXRAXX100-32, f
d
: 87Hz
DXRAXX112-12, f
d
: 87Hz
DXRAXX132-12, f
d
: 87Hz
DXRAXX132-22, f
d
: 87Hz
DXRAXX160-12, f
d
: 87Hz
DXRAXX160-22, f
d
: 87Hz
DXRAXX180-12, f
d
: 87Hz
DXRAXX180-22, f
d
: 87Hz
[C0087] Mot speed * 300 {1 rpm} 16000 Rated motor speed
Ã…
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
[C0088] Mot current * 0.5 {0.1 A} 300.0 Rated motor current
Ã…
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
[C0089] Mot frequency * 10 {1 Hz} 1000 Rated motor frequency
[C0090] Mot voltage * 50 {1 V} 500 Rated motor voltage
Ã…
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
[C0091] Mot cos phi * 0.50 {0.01} 1.00 Motor cos
Ö
Ã…
depends on C0086
l
Change of C0086 resets value to the assigned
default setting
18kHzsin Power optimised operation
C0105 QSP Tif 0.000 0,000 {0,001 s} 999.900 Deceleration time for quick stop (QSP)
Related to the speed change 0
¡
n
max.
C0254 Vp phase-CTRL 0.40 0.0000 {0.0001} 3.9999 V
p
Phase controller in MCTRL
[C0420] Encoder const 512 256 {1 inc/rev} 8192 Encoder constant for encoder input X8 in
increments per revolution
[C0490] Feedback pos 0 0{1}4Feedback system for position controller
l
C0490 = 0, 1, 2 can be mixed with C0495 = 0, 1, 2
l
0ResolveratX7
1 Encoder TTL at X8
2 Encoder sin at X8
3 Absolute ST at X8
4 Absolute MT at X8