Rated data, LongLife design, IP54/55
Holding brake 06 08
Power input
180 V DC W 20 25
Moment of inera kgcm² 0.15 0.61
Braking torque is stac Nm 4 8
Min. stac braking torque tolerance % -25 -25
Max. stac braking torque tolerance % 35 35
Reversing cycles
15x 10
6
15x 10
6
Repeve cycles
10x 10
6
10x 10
6
Maximum switching energy J 3000 7500
Manual release lever
When ordering, specify the posion of the manual release lever (T, L, R or B).
Terminal box and manual release lever are not possible in the same posion!
Δk
k
5
d
12
h
5
T B
L
R
Motor
Brake size
Dimensions
k
5
Δ k
h
5
d
12
mm
MSEMABR063-42 06 178 29 107 13
MSEMABR080-32 08 224 27 116 13
Product extensions
Brakes
Spring-applied holding brake