Troubleshooting and fault elimination
Error messages
10
l
EDK82MVXXX EN 1.0
3.2 LEDs at the controller (operating status display)
LED Operating status
green red
on off Controller enabled
on on Mains switched on and automatic start inhibited
blinking off Controller inhibited
off blinking every second Fault active, check under C0161
off blinking every 0.4 seconds Undervoltage switch-off
fast blinking off Motor parameter identification
3.3 Fault messages at the keypad or in the parameter setting
program Global Drive Control
Display Fault Cause Remedy
Keypad PC
1)
noer
0 No fault - -
ccr
71 System fault
Strong interferences on control cables Shield control cables
c
c
a
y
Ground or earth loops in the wiring
ce0
a
61 Communication error to AIF Transmission of control commands via AIF is
interfered
Plug the communication module firmly into the hand
terminal
ce1
a
62 Communciation error at
CAN-IN1 with sync control
CAN-IN1 object receives faulty data or
communication interrupted
Plug-in connection for bus module ó Check FIF
Check transmitter
Increase monitoring time under C0357/1 if necessary
ce2
a
63 Communication error to
CAN-IN2
CAN-IN2 object receives faulty data or
communication is interrupted
Plug-in connection for bus module ó Check FIF
Check transmitter
Increase monitoring time under C0357/2 if necessary
ce3
a
64 Communication error to
CAN-IN1 with event or time
control
CAN-IN1 object receives faulty data or
communication interrupted
Plug-in connection for bus module ó Check FIF
Check transmitter
Increase monitoring time under C0357/3 if necessary
ce4
a
65 BUS-OFF
(many c ommunication errors
occurred)
Controller has received too many faulty telegrams
via system bus and has been disconnected from the
bus
Check whether the bus terminator is available
Check screen contact of the cables
Check PE connection
Check the bus load, if necessary, reduce the baud rate
ce5
a
66 CAN Time-Out
With remote parameter setting via system bus
(C0370):
Slave does not r espond. Communication monitoring
time exceeded
Check wiring of the system bus
Check system bus configuration
OperationwithmoduleonFIF:
Internal error
Contact Lenze
ce6
a
67 Function module system bus
(CAN) is set to ”Warning” or
”BUS-OFF”
(only generated if C0128 = 1)
CAN controller sends ”Warning” or ”BUS-OFF” Check whether the bus is terminated
Check screen contact of the cables
Check PE connection
Check the bus load, if necessary, reduce the baud rate
EEr
a
91 External error (TRIP-SET) A digital signal used for the function TRIP set has
been activated.
Check external encoder
H05
a
105 Internal fault Contact Lenze
id1
a
140 Faulty parameter identification Motor not connected Connect motor
LP1
a
32 Error in motor phase
(only generated if C0597 = 1)
Failure of one/several motor phase(s)
Motor current too low
Check motor cables
V
min
boost
C
t
t
i
t
h
d
i
d
t
LP1
182 Error in motor phase
(only generated if C0597 = 2)
m
i
n
Connect motor with corresponding power or adapt
motor under C0599
LU
1030 DC-bus undervoltage
Mains voltage too low Check mains voltage
L
U
c
g
DC-bus voltage too low Check supply module
400 V controller connected to 240 V mains Connect the controller to the appropriate mains voltage