Operating instructions i510 cabinet frequency inverter | 10
© 11/2021 · EN · www.Lenze.com
Mechanical installation
Dimensions and assemblyPreparation
E1
H
H1
B1
T
E2
B
Dimensions and assembly
NOTE
The specied installation clearances are minimum dimensions to ensure a sucient air
circulation for cooling purposes. They do not take into account the bending radii of the
connecting cables.
Several i5xx cabinet inverters can be mounted directly next to each other, regardless of the
device size. No installation clearance is required between the devices.
Inverter
Rated power Weight H W D H1 W1
Screws
E1 E2
[kW] [kg] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1-phase mains connection 230/240 V devices
I51AExxxB
0.25 ... 0.37 0.75 155 60 130
165 - 2x M5 >50 >50
I51AExxxB
0.55 ... 0.75 0.95 180 60 130
190 - 2x M5 >50 >50
I51AExxxB
1.1 ... 2.2 1.35 250 60 130
260 - 2x M5 >50 >50
1-/3-phase mains connection 230/240 V devices
I51AExxxD 0.25 ... 0.37 0.75 155 60 130
165 - 2x M5 >50 >50
I51AExxxD 0.55 ... 0.75 0.95 180 60 130
190 - 2x M5 >50 >50
I51AExxxD 1.1 ... 2.2 1.35 250 60 130
260 - 2x M5 >50 >50
I51AExxxC 4 ... 5.5 2.1 250 90 130
260 30 4x M5 >50 >100
3-phase mains connection 400/480 V devices
I51AExxxF 0.37 0.75 155 60 130
165 - 2x M5 >50
>50
I51AExxxF 0.55 ... 0.75 0.95 180 60 130
190 - 2x M5 >50
>50
I51AExxxF 1.1 ... 2.2 1.35 250 60 130
260 - 2x M5 >50
>50
I51AExxxF 3 ... 4 2.3 250 90 130
260 30 4x M5 >50
>100
I51BExxxF 3 ... 4 1.35 250 60 130
260 - 2x M5
>50 >50
I51AExxxF 5.5 2.3 250 90 130
260 30 4x M5 >50
>100
I51AExxxF 7.5 ... 11 3.7 276 120 130
285 60 4x M5
>50 >100
I51BExxxF 7.5 ... 11 3.7 276 120 130
285 60 4x M5
>50 >100