Inverter   i550-C3.0/400-3 i550-C4.0/400-3 i550-C5.5/400-3 i550-C7.5/400-3
Rated power kW P
N
4 5.5 7.5 11
Rated power hp P
N
5 7.5 10 15
Mains voltage range   3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage   3 AC 0-400/480 V
Rated mains current      
  without mains choke A I
r, AC
10.3 14 18.3 28
  with mains choke A I
r, AC
8.2 11 14.5 22
Apparent output power kVA A
ON
5.9 8 10.5 15
Rated output current      
  2 kHz A I
OUT
8.8 11.9 15.6 23
  4 kHz A I
OUT
8.8 11.9 15.6 23
  8 kHz A I
OUT
- - - -
  16 kHz A I
OUT
- - - -
Power loss      
  2 kHz W 94 125 163 238
  4 kHz W 100 133 173 253
  8 kHz W - - - -
  16 kHz W - - - -
  at inverter disablecontroller
inhibit
W 6 6 6 6
Overcurrent cycle 180 s      
  Max. output current A I
max, out
11 14.3 19.5 23.6
  Overload me s t
ol
60 60 60 60
  Recovery me s t
re
120 120 120 120
  Max. output current during the
recovery me
A 5.5 7.1 9.8 12.4
Overcurrent cycle 15 s      
  Max. output current A I
max, out
14.6 19 26 33
  Overload me s t
ol
3 3 3 3
  Recovery me s t
re
12 12 12 12
  Max. output current during the
recovery me
A 5.5 7.1 9.8 12.4
Cyclic mains switching   3 mes per minute
Brake chopper      
  Max. output current A I
max, 1
9.5 16.6 16.6 29
  Min. brake resistance Ω R
min
82 47 47 27
Max. motor cable length shielded      
  without EMC category m 100 100 100 100
  Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - -
  Category C2 (2 kHz, 4 kHz, 8
kHz)
m 20 20 20 20
  Category C3 (2 kHz, 4 kHz, 8
kHz)
m 35 35 35 50
Weight kg 2.3 2.3 2.3 3.7
Weight lb 5 5 5 8
Technical data
3-phase mains connecon 400 V "Light Duty"
Rated data
138