Parameter Name / value range / [default seng] Info
0x2389:001
(P517.01)
PROFINET error: Error 1
(PROFINET error: Error 1)
•
Read only
•
From version 02.00
The parameter currently contains the error detected on the network.
•
The error values may occur in combinaon with the error values from
parameter 0x2389:002 (P517.02).
0 No error
1 Reserved
2 Unit ID unknown
3 Max. units exceeded
4 Invalid size
5 Unit type unknown
6 Runme plug error
7 Invalid argument
8 Service pending
9 Stack not ready
10 Command unknown
11 Invalid address descriptor
0x2389:002
(P517.02)
PROFINET error: Error 2
(PROFINET error: Error2)
•
Read only
•
From version 02.00
The parameter currently contains the error detected on the network.
•
The error values may occur in combinaon with the error values from
parameter 0x2389:001 (P517.01).
Bit 7 IP address error The IP address is invalid. Valid IP addresses are dened according to RFC
3330.
Bit 8 Staon name problem The staon name must be assigned according to the PROFINET specica-
on.
Bit 9 DataExch le
Bit 10 Stack boot error
Bit 11 Stack online error
Bit 12 Stack state error
Bit 13 Stack revision error
Bit 14 Inializaon problem
Bit 15 Stack init error The stack cannot be iniated with the user specicaons. A reason
might be, e. g., a staon name that does not correspond to the PROFI-
NET specicaon.
Related topics
4PROFINET ^ 365
6.2.4.6 EtherCAT diagnoscs
The following parameters serve to diagnose the EtherCAT interface and the communicaon
via EtherCAT.
Precondions
The control unit (CU) of the inverter is provided with EtherCAT (from rmware 02.00).
Parameter Name / value range / [default seng] Info
0x1000 Device type
•
Read only
•
From version 02.00
CANopen device prole according CANopen specicaon CiA 301/
CiA 402.
0x1008 Manufacturer device name
•
Read only
•
From version 02.00
Display of the manufacturer device name.
0x1009 Manufacturer hardware version
•
Read only
•
From version 02.00
Display of the manufacturer hardware version.
0x100A Manufacturer soware version
•
Read only
•
From version 02.00
Display of the manufacturer soware version.
0x1018:001 Identy object: Vendor ID
•
Read only
•
From version 02.00
Display of the manufacturer's idencaon number.
Diagnoscs and fault eliminaon
Diagnoscs parameter
Network diagnoscs