Display code Short designaon Default seng Seng range Address Category
P301.00 Modes of op. MS: Velocitymode [-2] Selecon list 0x6060 general
P302.00 V/f charac.shape Linear [0] Selecon list 0x2B00 general
P303.xx V/f shape data
└ P303.01 Base voltage 230 V * 0 ... 5000 V 0x2B01:001 MCTRL
└ P303.02 Base frequency Device for 50-Hz mains:
50 Hz
Device for 60-Hz mains:
60 Hz *
0 ... 1500 Hz 0x2B01:002 MCTRL
└ P303.03 Midpoint voltage 0 V 0 ... 5000 V 0x2B01:003 MCTRL
└ P303.04 Midpoint freq 0 Hz 0 ... 1500 Hz 0x2B01:004 MCTRL
P304.00 Limit. rotaon Both rot. direct [1] Selecon list 0x283A general
P305.00 Switching freq. 0 * Selecon list 0x2939 general
P306.xx Inv. load char.
└ P306.01 Duty selecon Heavy Duty [0] Selecon list 0x2D43:001 general
P308.xx Motor overload
└ P308.01 Max.load.for 60s 150 % 30 ... 200 % 0x2D4B:001 general
└ P308.02 Speed comp. On [0] Selecon list 0x2D4B:002 general
└ P308.03 Response Fault [3] Selecon list 0x2D4B:003 general
P309.xx Mot.temp.monit.
└ P309.02 Response Fault [3] Selecon list 0x2D49:002 general
P310.xx Mot.phase.fail.
└ P310.01 Response No response [0] Selecon list 0x2D45:001 general
└ P310.02 Current thresh. 5.0 % 1.0 ... 25.0 % 0x2D45:002 general
└ P310.03 Voltage thresh. 10.0 V 0.0 ... 100.0 V 0x2D45:003 general
P315.xx Slip compens.
└ P315.01 Slip: gain 100.00 % -200.00 ... 200.00 % 0x2B09:001 general
└ P315.02 Filter me 100 ms 1 ... 6000 ms 0x2B09:002 general
P316.xx V/f boosts
└ P316.01 Fixed V/f boost 2.5 % * 0.0 ... 20.0 % 0x2B12:001 MCTRL
└ P316.02 Dynam. V/f boost 0.0 % 0.0 ... 20.0 % 0x2B12:002 general
P317.xx Skip frequencies
└ P317.01 Skip frequency 1 0.0 Hz 0.0 ... 599.0 Hz 0x291F:001 general
└ P317.02 Skip bandwidth 1 0.0 Hz 0.0 ... 10.0 Hz 0x291F:002 general
└ P317.03 Skip frequency 2 0.0 Hz 0.0 ... 599.0 Hz 0x291F:003 general
└ P317.04 Skip bandwidth 2 0.0 Hz 0.0 ... 10.0 Hz 0x291F:004 general
└ P317.05 Skip frequency 3 0.0 Hz 0.0 ... 599.0 Hz 0x291F:005 general
└ P317.06 Skip bandwidth 3 0.0 Hz 0.0 ... 10.0 Hz 0x291F:006 general
P318.xx Oscillat. damp.
└ P318.01 Gain 150 % -400 ... 400 % 0x2B0A:001 MCTRL
└ P318.02 Filter me 30 ms 1 ... 600 ms 0x2B0A:002 MCTRL
P319.00 Field weak thold 0.0 Hz -599.0 ... 599.0 Hz 0x2B0C general
P320.xx Motor parameters
└ P320.04 Rated speed Device for 50-Hz mains:
1450 rpm
Device for 60-Hz mains:
1750 rpm
50 ... 50000 rpm 0x2C01:004 MCTRL
└ P320.05 Rated frequency Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
1.0 ... 1000.0 Hz 0x2C01:005 MCTRL
└ P320.06 Rated power 0.25 kW * 0.00 ... 655.35 kW 0x2C01:006 MCTRL
└ P320.07 Rated voltage 230 V * 0 ... 65535 V 0x2C01:007 MCTRL
└ P320.08 Cosine phi 0.80 0.00 ... 1.00 0x2C01:008 MCTRL
P322.00 Max motor speed 6075 rpm 0 ... 480000 rpm 0x6080 general
P323.00 Motor current 1.700 A * 0.001 ... 500.000 A 0x6075 MCTRL
* Default seng depending on the size. Firmware version 05.00.00.00