16.4.2 Basic seng and opons
Addressing the system bus nodes
The rst device in the system bus network is always acve as EtherCAT master. In addion,
this device is also an internal EtherCAT slave, which e. g. provides a DC master (Distributed
Clock
s).
The slave devices at the system bus are addressed via their acve EtherCAT staon address.
This address is assigned by the master while the system bus is inialised:
The in
ternal slave in the master device has the address "1001".
The rst slave in the network has the address "1002".
The sec
ond slave in the network has the address "1003" etc.
Master/slave funconality
The 0x2371:009 parameter is used to set the funconality of the system bus interface of the
inverter (EtherCAT master/slave).
Parameter
Address Name / seng range / [default seng] Info
0x2371:009 EtherCAT on board: Interface mode
Seng can only be changed if the inverter is inhibi-
t
ed.
Selecon of the master/slave funconality for the EtherCAT interface.
For acvang this seng, save the parameter set and restart the device.
0 Slave Acvaon of the slave funconality.
1 Master Acvaon of the master funconality.
Conguring the network
E
therCAT system bus
Basic seng and opons
345

Table of Contents

Other manuals for Lenze I95AE240F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I95AE240F and is the answer not in the manual?

Lenze I95AE240F Specifications

General IconGeneral
BrandLenze
ModelI95AE240F
CategoryInverter
LanguageEnglish

Related product manuals