Electrical installation
Connection terminals
6
EDKMF2102 DE/EN/FR 8.0
65
H2 DatenAnschlKlemmen−eigenschaft RS232
Connection terminals
Area Values
Electrical connection Plug connector with screw connection
Possible connections
rigid:
1.5 mm
2
(AWG 16)
flexible:
without wire end ferrule
1.5 mm
2
(AWG 16)
with wire end ferrule, without plastic sleeve
1.5 mm
2
(AWG 16)
with wire end ferrule, with plastic sleeve
1.5 mm
2
(AWG 16)
Tightening torque 0.5 ... 0.6 Nm (4.4 ... 5.3 lb−in)
Stripping length 6 mm