Assembly of lockable manual release lever in operang posion
1
2
3
4
5
1 Cheese head screw with hexagon nut 4 Manual release lever
2 Manual release shackle 5 Fan cover
3 Terminal block
How to mount the manual release lever
1.
Screw the cheese head screw with hexagon nut (1) loosely into the terminal block (3).
2.
Push the terminal block (3) over the manual release lever (4).
3.
Guide the manual release lever with terminal block (3+4) through the slot in the fan cover
(5) and screw it into the threaded hole in the manual release shackle (4).
4.
Tighten the manual release lever (4) to the prescribed torque.
5.
Align the terminal block (3) (see g.) and insert it from above into the slot of the fan cover
(5) up to the stop.
6.
Tighten the cheese head screw (1) to the specied torque and counter with hexagon head
screw.