Electrical installation
Plug connectors
Power connections / holding brake
6
30
Lenze • BA 33.0006 • 5.1
6.3.1 Power connections / holding brake
6-pole (external view of poles)
Contact Name Meaning M23
1
2
BD1
BD2
Holding brake +
Holding brake -
1
2
4
5
6
PE PE conductor
4
5
6
U
V
W
Power phase U
Power phase V
Power phase W
MCA 19...21, MCS 14...19, MQA 20 (external view of poles)
Contact Name Meaning M40
1
2
Not assigned
+
-
BD1
BD2
Holding brake +
Holding brake -
PE PE conductor
U
V
W
U
V
W
Power phase U
Power phase V
Power phase W
6.3.2 Fan
Single-phase (external view of poles)
Contact Name Meaning M17
PE PE conductor
1
2
4
5
6
3
1
2
U1
U2
AC fan
3 Not assigned
4
5
U+
U-
DC fan
6 Not assigned
8-pole (external view of poles)
Contact Name Meaning M23
PE PE conductor
2
1
3
A
B
C
D
1
2
3
Not assigned
A
B
U1
U2
AC fan
C
D
U+
U-
DC fan
Three-phase (external view of poles)
Contact Name Meaning M17
PE PE conductor
1 U Fan
2 Not assigned
3 V Fan
4
Not assigned
5
6 W Fan