EasyManua.ls Logo

Lenze MCS - Power Connections; Holding Brake; Fan

Lenze MCS
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical installation
Plug connectors
Power connections / holding brake
6
30
Lenze BA 33.0006 5.1
6.3.1 Power connections / holding brake
6-pole (external view of poles)
Contact Name Meaning M23
1
2
BD1
BD2
Holding brake +
Holding brake -
1
2
4
5
6
PE PE conductor
4
5
6
U
V
W
Power phase U
Power phase V
Power phase W
MCA 19...21, MCS 14...19, MQA 20 (external view of poles)
Contact Name Meaning M40
1
2
Not assigned
+
-
BD1
BD2
Holding brake +
Holding brake -
PE PE conductor
U
V
W
U
V
W
Power phase U
Power phase V
Power phase W
6.3.2 Fan
Single-phase (external view of poles)
Contact Name Meaning M17
PE PE conductor
1
2
4
5
6
3
1
2
U1
U2
AC fan
3 Not assigned
4
5
U+
U-
DC fan
6 Not assigned
8-pole (external view of poles)
Contact Name Meaning M23
PE PE conductor
2
1
3
A
B
C
D
1
2
3
Not assigned
A
B
U1
U2
AC fan
C
D
U+
U-
DC fan
Three-phase (external view of poles)
Contact Name Meaning M17
PE PE conductor
1 U Fan
2 Not assigned
3 V Fan
4
Not assigned
5
6 W Fan

Other manuals for Lenze MCS