Commissioning and operation
Functional test
8
38
Lenze BA 33.0006 5.1
8.3 Functional test
Check all functions of the drive after commissioning:
Direction of rotation of the motor
Direction of rotation in the disengaged state (see c hapter ”Electrical
connection”).
Torque behaviour and current consumption
Function of the feedback system
8.4 During operation
Stop!
Fire hazard! Do not clean or spray motors with flammable detergents
or solvents.
Avoid overheating! Deposits on the drives impede the heat dissipation
required and have to be removed regularly.
Danger!
During operation, motor surfaces must not be touched. According to the
operating status, the surface temperature for motors can be up to 140°C.
For the protection against burn injuries, provide protection against
contact, if necessary. Observe coolingoff times!
During operation, carry out inspections on a regular basis. Pay special attention to:
Unusual noises
Oil spots on drive end or leakages
Irregular running
Increased vibration
Loose fixing elements
Condition of electrical cables
Speed variations
Impeded heat dissipation
Deposits on the drive system and in t he cooling channels
Pollution of the air filter
In case of irregularities or faults: 45.