EasyManua.ls Logo

Lenze MOBILE DCU - DC;AC inverter

Lenze MOBILE DCU
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Rated data of the devices for HV on−board supply system 800 V
DC/AC inverter
4
Ò
27
EDSMDAG EN 2.0
4.2.2 DC/AC inverter
DC/AC inverter 7.5 kW 11 kW 15 kW 22 kW 30 kW 60 kW
Input voltage − HV on−board supply system
Rated voltage V DC 800
Voltage range V DC 100...848
Output voltage 3 AC 0V...510V
Output frequency f
out
Hz −599...+599
Switch−off at short−circuit current A 24 36.1 48.1 72.1 96.2 192.3
Continuous operation
Current consumption − HV
on−board supply system
A 9.8 13.5 18.4 26.3 39.2 71
Output power kW 5 7.3 10 14.7 20 40
Output current at
f
out
<5Hz
2 kHz,
permanent
A 8 11 15 21.5 32 58
4 kHz,
permanent
A 6.4 8.8 12 17.2 25.6 46.4
8 kHz,
permanent
A 4.8 6.6 9 12.9 19.2 34.8
16 kHz,
permanent
A 2.4 3.3 4.5 6.5 9.6 17.4
4 kHz auto A 8 11 15 21.5 32 58
8 kHz auto A 7.2 9.9 13.5 19.4 28.8 52.2
16 kHz auto A 4.4 6.1 8.3 11.8 17.6 31.9
Output current at
f
out
>5Hz
2 kHz,
permanent
A 12.8 17.6 24 34.4 51.2 92.8
4 kHz,
permanent
A 10 13.8 18.8 26.9 40 72.5
8 kHz,
permanent
A 7.2 9.9 13.5 19.4 28.8 52.2
16 kHz,
permanent
A 4 5.5 7.5 10.8 16 29
4 kHz auto A 10 13.8 18.8 26.9 40 72.5
8 kHz auto A 8 11 15 21.5 32 58
16 kHz auto A 4.8 6.6 9 12.9 19.2 34.8
Output current for "socket" application (VAC)
f
out
<10Hz, VAC 16 kHz,
permanent
A 2.8 3.9 5.3 7.5 10.6 18.6
f
out
>10Hz, VAC 16 kHz,
permanent
A 5 6.9 9.5 13.5 18.9 34.2

Table of Contents

Related product manuals