Electrical installaon
Mains connecon
NOTICE
Incorrect arrangement in the control cabinet.
Malfuncon of the device.
▶
When installing the devices into a control cabinet with a spaal distance, separate the devices that
generate high voltage and electromagnec interference from extra-low voltage devices such as the IoT
Gateway x500.
NOTICE
Unstable LAN connecon due to wrong cable types.The LAN connecon might be interrupted.
▶
Only use cables of CAT5-S/FTP type or beer.
SELV/PELV
(LPS)
L1
N
PE
L1
N
0V
+24
~ =
F
(max. 4 A)
PE
IoT Gateway x500
24E
DI1
GND
Mains connecon
Connecon X50
GND
24E
DI1
Digital control signal
+
-
+
-
12-24 V DC
Connecon type Connector
Weidmüller BL
5.08/04/180 SN BK BX
Min. cable cross-secon mm² 0.75 (AWG18)
Max. cable cross-secon mm² 1.5 (AWG14)
Stripping length mm 7
Tightening torque Nm 0.4
Digital input DI1
Voltage range 0 - 29 V DC
Current range (ON) 2 - 5 mA
Voltage range (LOW) 0 - 3 V DC
Voltage range (HIGH) 7 - 29 V DC
By default, the digital input is not congured and does not need to be wired. The digital input provides the
opportunity to locally acvate/deacvate the VPN connecon of the IoT Gateway x500 (ON/OFF).
Electrical installaon
Mains connecon
27