EasyManua.ls Logo

Lexmark C752 - Page 261

Lexmark C752
425 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PostScript
4-78
MaxSourceList integer (Read-only) See Table C-4 on page C-8 for the default value
of your printer.
MaxUPathCache integer Maximum bytes occupied by the user path cache.
Legal value: Any non-negative integer.
PageCount integer (Read-only) Total number of pages that have been printed.
PanelCode
1
string (Read-only) Version of the operator panel code.
PrinterCode
1
string (Read-only) Firmware version of the printer controller card.
PrinterName string Initialized from the printer name stored in NVRAM (the default
name of the printer). If this parameter is set to a zero length
string, the PrinterName is set to the value of the product
string in statusdict.
Legal value: Any string of 32 or fewer non-null characters.
RamSize integer (Read-only) Total amount of memory (in bytes) installed in the
printer.
RealFormat string (Read-only) Preferred representation for real numbers in
binary encoded tokens.
Revision integer (Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.
SearchBuiltinFontsFirst
1
boolean Controls the device search order the interpreter uses to
locate fonts.
SerialNumber
1
string (Read-only) Serial number of your printer.
StartJobPassword string (Write-only) Controls the ability of the startjob operator to
alter initial Virtual Memory (VM).
Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.
StartupMode integer Controls the system start file (Sys/Start) during PostScript
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.
0 Disable use of Sys/Start file and Job/Start file.
1 Sys/Start file executes (if present on disk or flash).
10 Job/Start file executes before each user job.
11 Both files run (a combination of 1 and 10).
Legal Values: 0 <= x <= 255. Values other than the four listed
are equivalent to 0.
Note: If both flash and disk have a Sys/Start file and Job/Start
file, the value of the SearchOrder for the two devices
determines which file is executed.
StaticRamSize
1
integer (Read-only) Amount of static memory (in bytes) on the
controller board.
Table 4-13: PostScript Emulation System Parameters (Continued)
Key Type Definition
1
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
These parameters are available with the Adobe PostScript Language Supplement 3010.
3
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 3010.

Table of Contents

Other manuals for Lexmark C752

Related product manuals