Diagnostics information 2-25
4513-630, -63W, -6EW
Dead machine service check
CAUTION: Check the AC line voltage. The voltage should be within the following limits:
100 V ac (volts alternating current) – 127 V ac for the 110 V printer
200 V ac – 240 V ac for the 220 V printer
FRU Action
LVPS/HVPS
Unplug the printer. Remove the LVPS/HVPS, and check the fuses for continuity.
If open, then replace the LVPS/HVPS.
If not open, then check the switch continuity across its conductors with the switch on.
Turn the switch off. Plug the AC line into the LVPS/HVPS and switch unit on.
Note: Voltages may be exposed at several places on the board. Do these verifications, and
then unplug the card:
If voltages are not correct, then replace the LVPS/HVPS.
If voltages are correct, then check the controller board. See “Controller board service
check” on page 2-23.
Pins Voltage
CN201-6, 17,
19
+24 V dc
CN201-10, 12,
14, 16, 18
Ground
CN201-1,3, 5,
11,13, 15
+5 V dc