Clearance requirements
Model Left side Right side Front Rear Top
X548de,
X548dte
76.2 mm (3 in.) 254 mm (10 in.) 508 mm (20 in.) 101.6 mm (4 in.) 360 mm (14 in.)
Environmental conditions
Note: When shipping or storing printers, always pack the printer supplies (such as cartridges and photoconductors)
separately.
Printer air temperature ranges
Printer
model
Operating value Shipping and storage value
(printer with cartridges)
Product operating Product in poweroff mode Packaged
X548de,
X548dte
15.6°C to 32.20°C (60°F to 90.0°F) 10.0°C to 43.3°C (50°F to 110°F) 40°C to 43.3°C (40°F to 110°F)
Values for the printer wetbulb temperature and the ambient operating environment
Printer
model
Operating value Shipping and storage
value
Wetbulb temperature
(product operating)
Wetbulb temperature
(product in poweroff
mode)
Ambient operating
environment
Wetbulb temperature
(product in poweroff
mode)
X548de,
X548dte
22.80°C (73.0°F) maximum 26.70°C (80.10°F)
maximum
15.6°C to 32.C (60°F to
90°F)
8–80% RH
26.70°C (80.10°F)
maximum
Printer humidity ranges
Printer
model
Operating value Shipping and storage value
Air relative humidity (RH) Air relative humidity (RH)
(unpackaged)
Air relative humidity (RH)
(packaged)
X548de,
X548dte
8–80% 8–80% 5–95%
Cartridge air temperature ranges
Printer model Shipping and storage value
Cartridges (packaged)
X548de, X548dte 40°C to 43.3°C (40°F to 110°F)