Installation
46
GA02412_002_C0 - 10/2016 - © Leybold
Do not unplug the connectors of the SP Guard while still being under volt-
age. There exists the risk of igintion!
All connectors are protected against mechanical influences thanks to the
housing covers. Do not operate the pump without its covers!
Outputs at the SP-Guard (S1 - S4)
The outputs S1 - S4 of the SP-Guard are provided with push-pull driver out-
put stages (transistor connection between +Vcc and GND). Correspondingly,
the high level is at 1 V below the power supply voltage level and the low level
is at approximately 1 V.
The maximum current rating is 40 mA.
The outputs are protected by means of semiconductor fuses.
CAUTION
Fig. 3.8 Electrical connection - Power supply for status outputs
Fig. 3.9 Signal output diagram
24 V
(S1... S4)
∆U . 1 V
∆U < 1 V
0 V
SP - Guard
Sensors
Mains connection
~
~
1 / white
4 / green
11 / violet
16 / yellow/brown
12 / grey/pink
13 / red/blue
SPS
2 / brown
S1
S2
S4
+ 24 V DC
0 V DC
S3
15 / brown/green
PE
L1
N
PE
Power supply
14 / white/green
GND
GND
6 / grey
0V
0V
optional
optional
Shield
Filter
Jumper
optional