5.9 Removing and Remounting the Pump Module
Required tools:
Allen keys size 3, 4, 6 and 8 mm, box wrench size 8 and 13, possibly pliers,
torque wrench.
Required spare parts:
Gasket (14/4) For material No., see spare parts list
5.9.1 Removing the Pump Module
Drain the oil and remove the oil case (see Chapter 5.6).
Unscrew the hex. nuts (14/1).
Pull the entire pump module (14/2) forward off the tie rods (14/6).
When doing so, ensure that the individual pin-fitted parts are not
loosened. Further disassembly of the pump module should only be carried
out by a trained service engineer.
Remove the gasket (14/4).
Remove the coupling element (14/5).
Maintenance
NOTICE
Fig. 14 Removing and remounting the pump module
1 Hex. nuts
2 Pump module
3 Washer
4 Gasket
5 Coupling element
6 Tie rods