Description
9
GA 01.600/10.02 - 07/01
1.4 Technical Data
Nominal pumping speed* 50/60 Hz m
3
·h
-1
6/7,3 12/14,6 21/23,6
Pumping speed 50/60 Hz m
3
·h
-1
5,2/6 9,9/11,3 16/19
Ult.partial pressure without gas ballast mbar ≤5 x 10
-4
≤5 x 10
-4
≤5 x 10
-4
Ult.total pressure without gas ballast** mbar ≤2 x 10
-3
≤2 x 10
-3
≤2 x 10
-3
Ult.total press.w.gas ballast (stage 2)** mbar ≤3 x 10
-2
≤3 x 10
-2
≤3 x 10
-2
Water vapour tolerance
Stage 1 mbar 10 10 10
Stage 2 mbar 30 20 20
Stage 3 mbar 40 30 30
Connection port DN 16 KF 25 KF 25 KF
Noise level (50 Hz) dB (A) ≤49 ≤49 ≤52
Permissible ambient temperature °C 10 bis 50 (EURO - Motor) / 10 to 40 (USA/Japan - Motor)
Oil filling max./min l 1,25/0,75 1,25/0,75 1,25/0,75
Motor power 50/60 Hz W 450/550 450/550 700/850
Speed 50/60 Hz rpm 1350/1650 1350/1650 1380/1650
Protection IP 54 54 54
Weight with operating agent***kg kg 22,1 24,2 30,7
Dimensions (W x H x D)*** mm 156 x 258 x 416 156 x 258 x 435 170 x 258 x 494
* to DIN 28 426 T1 ** to DIN 28 4oo and subsequent numbers *** Dimensions and weights with Euro motor
D 5 E D 10 E D 16 E
1.4.1 Motor Dependent Data
Euro 1~ 220-240/230 50/60 ±5 % 450/540 2,5/2,4 10 54 1350/1650
Three-ph.motor ∆220-240/ 50 ±5 % 550 2,8 6 54 1500
3~ Y 346/415 1,6
∆200-266/ 60 ±5 % 650 2,8 6 54 1800
Y 346-460 1,6
Euro 1~ 220-240/230 50/60 ±5 % 450/540 2,5/2,4 10 54 1350/1650
Three-ph.motor ∆220-240/ 50 ±5 % 550 2,8 6 54 1500
3~ Y 346/415 1,6
∆200-266/ 60 ±5 % 650 2,8 6 54 1800
Y 346-460 1,6
Wide voltage- 110-120; 50/60 ±5 % 490/550 6,8/5,6 10 54 1350/1650
motor 1~ 208-240 3,4/2,8
Euro 1~ 220-240 50/60 ±5 % 700/850 5,3/4,6 10 54 1380/1650
Three-ph.motor ∆220-240/ 50 ±5 % 650 4 10 54 1430
3~ Y 346-415 2,3
∆200-277/ 60 ±5 % 750 3,6 10 54 1720
Y 346-480 2,1
Motors for Voltage FrequencyVoltage Power consumption Nom.currentFuse* ProtectionNom.speed
D 5 E (V) (Hz) tolerance (W) (A) (A) IP (rpm)
Motors for Voltage FrequencyVoltage Power consumption Nom.currentFuse* ProtectionNom.speed
D 10 E (V) (Hz) tolerance (W) (A) (A) IP (rpm)
Motors for Voltage FrequencyVoltage Power consumption Nom.currentFuse* ProtectionNom.speed
D 16 E (V) (Hz) tolerance (W) (A) (A) IP (rpm)
*The values stated for the fuses are recommended values only
Values for up-front fuses for short circuit protection.Please take note of the information provided by the manufacturers of contactors and motor protection switches.