- 8 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
# Caution) Must keep power-on more than 3 seconds after AC Power-on first time.
3.2.4 Color coordinates adjustment and Luminance adjustment.
3.2.4.1 Color coordinates adjustment
■ Monitor Contrast / Brightness
- Energy saving : LOW
- Brightness : 100(Max)
■ CA-110/CA-210: Set “Channel 7” CA-110: channel: 8. CA-210: channel 14
■ Signal Generator : At cut-off and drive 16 step pattern for ADC
- Output Voltage : 700 mVp-p
- Output Mode : Mode 12( 1920x1080@60Hz )mode Setting.
3.2.4.2.Adjustment : Board Assembly Line
27MP59HT/24 MP59HT use internal ADC, no need connect Dsub cable
Internal ADC steps as below
On AC power on with Aging mode, checking the ADC values and then decide to do or not,
If don’t use internal ADC ,please follow below step
Input 16 step pattern for ADC (Mode12, pattern 11). (Video level : 700 mVp-p)
Adjust by commanding AUTO_COLOR_ADJUST
Confirm “Success” message in Screen or Check the data of 0xFD, 0xFE address of
EEPROM(0xA6) is 0xAA after waiting 5 seconds
If there is “FAULT” message or the data of 0xFD, 0xFE address of EEPROM(0xAA) is not
0xAA, do adjust again
If all Adjustment is completed, the values of WARM(6500K), User Color and COOL(9300K)
are saved automatically.
3.2.
4.3. Confirm at Total Assembly Line: adjustment
Check the data of 0xFD, 0xFE address of EEPROM(0xA6) is 0xAA.
If the data of 0xFD, 0xFE address of EEPROM(0xA6) is not 0xAA, do adjust again by
3.2.4.2.
•