- 11 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Other model if need input EDID on the line, please refer below steps:
Confirm whether module selection is correct or not on the self-diagnostics OSD
with signal cable disconnected.
Connect HDMI Signal Cable to DVI-D wafer.
Write EDID DATA to
EEPROM(24C02) by using DDC2B protocol.
Check whether written EDID data is correct or not.
-
.- Analog part EDID data
Connect analog Signal Cable to D-sub wafer.
Write EDID DATA to
EEPROM(24C16) by using DDC2AB protocol.
* check the line EEPROM flag :EEPROM address:A6,FA data:0x1F
If NG ,pls press every key ,then check again.
Key_full_check_IT
_SW_121122.ppt
Check whether written EDID data is correct or not.
(refer to Product spec).
After writing EDID, send Elapsed Time Clear command.
(Elapsed time should not be displayed, after EDID writing)
: Confirm periodically (in the first set of new lot, process change) whether module name and
aging time disappeared on the self-diagnostics OSD with signal cable disconnected.
If Elapsed Time Clear command isn’t executed, module name, aging time and TCO word appear
on the self-diagnostics OSD.(Module
name and aging time should not appear after writing EDID)
Make sure to do FACTORY RESET at the final process.
3.2.5.9. Shipping condition
Contrast : 70
Power Switch : Off
Brightness : “100(Max)”
Color Select : custom
Language Select : Refer to product spec.
OSD Position: Match Position with Key position
Power indicator : ON
Sound : ON
Check HDMI Audio headphone function, after check, please set signal source to
RGB Mode by Hand.
3.2.5.10 V-Com Adjustment