- 17 -
LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.
Only for training and service purposes
12 80 5-P
age 80~FF Read
13 AC 0 6-Page 0~7F Read
14 80 6-Page 80~FF Read
15 AE 0 7-Page 0~7F Read
16 80 7-Page 80~FF Read
4.6.3 Use
Read E
2
PROM’s specific area as unit of 128(80h)-byte. ( 84h )
4.6.4 EDID Write
EEPROM access by using DDC2B protocol
1-Byte write
L : 0x00~0x7F
D : data
8-byte write
L : 0x00,0x10,….0x70
4.6.5 EDID Read
DDC2B Command.(A0/A1)
- 128 Byte transfer of EDID Buffer of MICOM
5. Standard of Auto/Manual equipment adjustment
No
.
Item Adjustment & measurement
standard
Operation
mode
Operation
Pattern
Measurement
Position
1 Voltage(V) 5V± 0.3V / 3.3V±0.25V,
1.2V± 0.07
MODE 12
MSPG : 126
Pattern4 TP of
Each power
2 Color
coordinates
(9300/6500K)
Level
Auto Adjustment MODE 12
MSPG : 126
Pattern 0
Center
of Screen
3 Color
coordinates
(6500K)
DRIVE1 X 0.313±0.005 MODE 12
MSPG : 126
Pattern1
Center
of Screen
Y 0.329±0.005
Color
coordinates
(9300K)
DRIVE2
X 0.283±0.005
Y 0.298±0.005