EasyManua.ls Logo

LG 65VS10 - Page 56

LG 65VS10
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
31. Temperature value (Command: d n)
To read the inside temperature value.
Transmission
[d][n][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
32. Lamp fault Check (Command: d p)
To check lamp fault.
Transmission
[d][p][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
Data 00 : Lamp Fault
01 : Lamp Ok
02 : N/A (DPM/Power Off)
33. Auto volume (Command: d u)
Automatically adjust the volume level.
Transmission
[d][u][ ][Set ID][ ][Data][x]
Data 00: Off Data 01: On
Acknowledgement
[u][ ][Set ID][ ][OK/NG][Data][x]
34. Speaker (Command: d v)
Turn the speaker on or off.
Transmission
[d][v][ ][Set ID][ ][Data][x]
Data 00: Off Data 01: On
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x
35. Time (Command: f a)
Set the current time.
Transmission
[f][a][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
[Data1]
00 : Monday
01 : Tuesday
02 : Wednesday
03 : Thursday
04 : Friday
05 : Saturday
06 : Sunday
[Data2]
0H to 17H (Hours)
[Data3]
00H to 3BH (Minutes)
Acknowledgement
[a][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
*When reading data, FFH is inputted for [Data1],
[Data2] and [Data3]. In other cases, all are treated as
NG.