www.lg.com
INSTALLATION MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards
by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Air-to-Water Heat Pump (For High Temperature)
[
Representative
]
LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-
gu, Changwon-si, Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
P/NO : MFL67212813
ENGLISH
FRANÇAIS
ΕΛΛΗΝΙΚΆ

Questions and Answers

  • P
    Patrick JensenSep 14, 2025
    What does an inverter PCB EEPROM error mean on my LG AHNW166T0 and how can I fix it?
    • E
      Edward LopezSep 14, 2025
      If your LG Air Conditioner displays an inverter PCB EEPROM error, it means there is an error with the EEPROM on the inverter PCB. To resolve this, replace the EEPROM on the inverter PCB.
  • S
    Sabrina CampbellAug 25, 2025
    How to fix an LG Air Conditioner indoor and outdoor unit communication error?
    • M
      Michael CannonAug 25, 2025
      If your LG Air Conditioner displays a communication error between the indoor and outdoor units, it indicates that there's no signal communication between them. To address this, inspect the communication line connecting the indoor and outdoor units to ensure it is properly connected and free from damage.
  • P
    pmatthewsAug 25, 2025
    How to troubleshoot an air temperature sensor error on an LG Air Conditioner?
    • S
      Sharon MerrittAug 26, 2025
      An air temperature sensor error in your LG Air Conditioner usually indicates a disconnection or short circuit in the air temperature sensor. You should check the connections of the air temperature sensor to resolve this issue.
  • C
    Cheryl RyanAug 26, 2025
    What causes an inverter compressor overcurrent in an LG AHNW166T0 Air Conditioner and how to fix it?
    • D
      Daniel HayesAug 26, 2025
      If your LG Air Conditioner shows an inverter compressor overcurrent error, it could be due to an increase in the inverter compressor CT value. Check the CT value and make sure it's within the specified limits.
  • M
    Mr. Ronnie Villarreal DDSSep 15, 2025
    Why is my LG AHNW166T0 Air Conditioner's inverter heatsink temperature rising excessively?
    • C
      Christopher FrenchSep 15, 2025
      If your LG Air Conditioner shows an excessive rise in inverter heatsink temperature, it means the inverter PCB is generating too much heat, causing the heatsink temperature to rise. To resolve this, monitor the inverter PCB temperature and improve ventilation.
  • H
    hstricklandSep 23, 2025
    What does a high/low inverter input voltage error mean on my LG AHNW166T0?
    • V
      Victoria KleinSep 23, 2025
      If your LG Air Conditioner displays a high/low inverter input voltage, it means the inverter input voltage exceeds the unit limit and lasts for 4 seconds (173V ~ 289V). To resolve this, ensure that the inverter input voltage remains within the specified range.
  • M
    Mary BrooksSep 7, 2025
    Why is my LG AHNW166T0 Air Conditioner's inverter compressor failing to activate?
    • J
      Joseph ChristianSep 7, 2025
      If your LG Air Conditioner experiences an inverter compressor activation failure, it's due to an error with the inverter compressor causing it to fail during initial activation. You should inspect the inverter compressor for activation issues.
  • G
    Gregory PetersonSep 8, 2025
    What does an inverter PSC/PFC fault error mean on my LG AHNW166T0 Air Conditioner?
    • D
      Denise HicksSep 8, 2025
      If your LG Air Conditioner displays an inverter PSC/PFC fault error, it indicates an overcurrent at the inverter input. To resolve this, check for overcurrent conditions at the inverter input.
  • E
    Elizabeth SchwartzSep 2, 2025
    How to fix a low pressure sensor defect of the inverter compressor in my LG AHNW166T0 Air Conditioner?
    • D
      daniellemasonSep 2, 2025
      If your LG Air Conditioner shows a low pressure sensor defect for the inverter compressor, it indicates that the low pressure sensor is either disconnected or short-circuited. To resolve this, check the connections of the low pressure sensor.
  • J
    Jack MooreAug 31, 2025
    Why does my LG Air Conditioner show a communication error between the indoor and outdoor units?
    • G
      greggjohnsonAug 31, 2025
      If your LG Air Conditioner displays a communication error between the indoor unit and the outdoor unit main PCB, it means the outdoor unit isn't receiving a signal from the indoor unit. To fix this, inspect the communication line between the indoor and outdoor units.