EasyManua.ls Logo

LG LS-H0560CL - Page 10

LG LS-H0560CL
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
5. Forced operation
If you lose wireless remote controller, you can operate the unit with forced operation switch.
The standand conditions are as following.
Cooling Model
Operation Mode Cooling
Indoor FAN Speed High
Setting temp. 22°C
4. Soft Dry Operation Mode
During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compres-
sor OFF temperature is the setting temperature minus 0.5°C.
When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
The operation diagram is shown below.
INDOOR FAN LOW
Selecting
fan speed
ON ON ONOFF OFF
Operation
Cooling
Dry Operation
COMPRESSOR
SETTING TEMP.+1°C
(COMP. ON)
SETTING TEMP.-0.5°C
(COMP. OFF)
10 minutes
2 minutes
58 seconds
2 minutes
58 seconds
maximum
10 minutes
maximum
4 minutes

Related product manuals