6. The phenomena in case of connecting error
INDOOR UNIT
Connector Type
Condition
Open
Connecting reversely
Open
Open
Open
Open
Short between terminals
( and ) of ROOM-TH.
Short between terminals
All functions stop.
The operation with the remote controller, forced and
test one do not operate.
PWB pattern is damaged when applying the power.
The up/down vane does not operate.
The up/down vane does not smoothly operate.
It does not operate with a remote controller.
The operation indicator blinks once.
(on for 0.5 second, off for 3 seconds).
The compressor operates continuously regardless
of the setting temperature and the variation of room
temperature.
The operation indicator blinks once.
The compressor and the outdoor fan stop.
The indoor fan speed is low.
The indoor Fan does not operate.
CN-POWER
CN-MOTOR
CN-U/D
CN-DISP
CN-TH
Phenomena
On for 0.5 second
Off for 3 seconds