EasyManua.ls Logo

LG LS-H0560CL - Troubleshooting: Louver Operation; Vertical Louver Not Operating

LG LS-H0560CL
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
If the regular torque is detected when rotating the Vertical Louver with
hands Normal
Check the connecting condition of CN-U/D Connector.
Check the soldering condition(on PWB) of CN-U/D Connector.
Check the operating circuit of the Vertical Louver
Confirm that there is DC
+
12V between pin (RED) of CN-U/D and GND.
Confirm that there is a soldering short at following terminals.
- Between
58
,
59
,
60
and
61
of MICOM
- Between , , and of IC01M
- Between , , and of IC02M
If there are no problems after above checks.
Confirm the assembly conditions that are catching and interfering parts in
the rotation radial of the Vertical Louver.
5. When Vertical Louver does not operate.