EasyManua.ls Logo

LG LS-H0560CL - Troubleshooting: Electronic Parts; No Operation: Power and Component Checks; PCB Board Operation Checks

LG LS-H0560CL
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
1. Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Electronic Parts Troubleshooting Guide
Turn off Main Power.
Turn on Main Power.
Does "beeping" sound is made from the Indoor Unit?
Primarily, the operating condition of Micom is OK.
Check the voltage of power(About AC 220V/240V, 50Hz).
Main power's voltage
Voltage applied to the unit
Connecting method of Indoor/Outdoor connecting
cable
Check PWB Ass'y
- Fuse
- Pattern damage
- Varistor(ZNR01J)
Check the connection housing for contacting.
Connector related to CN-POWER
Connector related to CN-FAN
Connector contacting of Outdoor Fan/Compressor
Display PWB Ass'y
Check each load(Indoor/Outdoor Fan Motor,
Compressor, Stepping Motor) and contacting
condition of related connector.
PCB Board Operation Check
Items
Power Transformer
(Indoor unit)
- Input Voltage
- Output Voltage
IC01D(7812) Output
(Indoor/Outdoor unit)
IC02D(7805) Output
(Indoor/Outdoor unit)
IC4(KIA7036, Reset IC)
X01(8MHz)
Replace Trans
Replace IC01D
Replace IC02D
Replace faulty parts
- About AC220V/240V
±
10% - Check the power voltage
- About AC14
±
3V
DC
+
12V
DC
+
5V
Voltage of Micom No. 2,
(DC +4.5V over) and Soldering condition.
Content Remedy
NO
YES
(After 10 seconds)

Related product manuals