EasyManua.ls Logo

LG LS-H0560CL - Outdoor Unit Connections; Connecting Pipings to Outdoor Unit; Connecting Cable to Outdoor Unit

LG LS-H0560CL
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
1) Connecting the pipings to the Outdoor
unit
1. Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
When tightening the flare nut with torque
wrench, ensure the direction for tightening fol-
lows the arrow on the wrench.
2) Connection of the cable
1. Remove the cover control from the unit by loosen-
ing the screw.
Connect the wires to the terminals on the control
board individually as the following.
Cooling only type
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the cover control to the original position with
the screw.
Liquid side piping
(Smaller Dia.)
Gas side piping
(Bigger Dia.)
Torque wrench
Outdoor unit Outdoor unit
Liquid side piping
(Smaller Dia.)
Gas side piping
(Bigger Dia.)
Torque wrench
Connecting
cable
Terminal block
(Pillar terminal)
Cover control
Outdoor unit
Over
5mm
Holder for
connecting
cable
Terminal block
(Pillar terminal)
Connecting
cable
Holder for
connect cable
Cover control
Over
5mm
3. Connecting Pipings and the cable to Outdoor unit
Pipe Size Torque
Liquid Side (1/4") 1.8kg·m
Gas Side (3/8") 4.2kg·m
BROWN
1(L) 2(N)
BLUE
GREEN/YELLOW
Terminals on the outdoor unit
Terminals on the indoor unit
Color of Wires
1(L) 2(N)

Related product manuals