1) Connection of power supply
1. Connect the power supply cord to inde-pen-
dent power supply.
2. Prepare the remote control.
Insert two batteries provided.
Remove the cover from the back of the remote
control.
Slide the cover according to the arrow direction.
Insert the two batteries.
(Two R03 or AAA dry-cell batteries or equiva-
lent.)
Be sure that the (+) and (-) directions are cor-
rect.
Be sure that both batteries are new.
Re-attach the cover.
Slide it back into position.
3. Operate the unit at cooling operation mode for
fifteen minutes or more.
Anchor the outdoor unit with a bolt and nut (ø10cm)
tightly and horizontally on a concrete or rigid mount.
When installing on the wall, roof or rooftop, anchor
the mounting base securely with a nail or wire
assuming the influence of wind and earthquake.
In the case when the vibration of the unit is con-
veyed to the house, settle the unit with an anti-
vibration rubber.
2) Evaluation of the performance
1. Measure the temperature of the intake and dis-
charge air.
2. Ensure the difference between the intake tem-
perature and the discharge one is more than
8°C (Cooling) or reversely (Heating).
Bolt
Tubing connection
Discharge air
Settlement of Outdoor Unit
7. Test running