12 | PRODUCT DATA
Single Zone High Efciency Standard Wall Mount Engineering Manual
Due to our policy of continuous product innovation, some specications may change without notication.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
FUNCTIONS, CONTROLS, OPTIONS
Table 4: Indoor Units—Functions, Controls and Options.
Indoor Unit Type LS090HSV5 LS120HSV5 LS180HSV5
Airow
Air Supply Outlet
1 1 1
Airflow Direction Control (Left / Right)
5 Steps 5 Steps 5 Steps
Airflow Direction Control (Up / Down)
6 Steps 6 Steps 6 Steps
Auto Swing (Left / Right)
Auto Swing (Up / Down)
Fan Speed Airflow Steps (Fan / Cool / Heat)
6 / 6 / 6 6 / 6 / 6 6 / 6 / 6
Natural Wind (Auto Wind)
Jet Cool / Jet Heat (Power Wind)
√ / √ √ / √ √ / √
Comfort Air
Air
Purifying
Prefilter (Washable / Anti-fungal
1
)
3M Micro Dust Filter
Functions
Hot Start
Self Diagnostics
Defrost
Dry (Dehumidification) Operation
Auto Changeover
Auto Cleaning (Coil Dry)
Auto Restart Operation
Child Lock
1
Forced Operation
Sleep Mode
7 Hour 7 Hour 7 Hour
Timer (24 Hour On / Off)
Weekly Timer
1
Two Thermistor Control
1
Low Ambient Operation
Overheat Protection
Smart Diagnosis
Indoor Unit Display Type
Number Display Number Display Number Display
Indoor Unit Display Light
On / Off On / Off On / Off
Energy Saving
Mode Lock
Cooling Only Cooling Only Cooling Only
Central
Controllers
AC Smart IV
PACS4B000 PACS4B000 PACS4B000
ACP IV
PACP4B000 PACP4B000 PACP4B000
PI-485
PMNFP14A1 PMNFP14A1 PMNFP14A1
Remote
Controllers
MultiSITE CRC1
PREMTBVC0 PREMTBVC0 PREMTBVC0
MultiSITE CRC1+
PREMTBVC1 PREMTBVC1 PREMTBVC1
Integration
Solution
MultiSITE Communications Manager
PBACNBTR0A PBACNBTR0A PBACNBTR0A
Building
Network
Unit
LonWorks® Gateway
PLNWKB100 PLNWKB100 PLNWKB100
AC Smart IV BACnet® Gateway
PBACNA000 PBACNA000 PBACNA000
ACP IV BACnet Gateway
PQNFB17C2 PQNFB17C2 PQNFB17C2
Other
Dry Contact
PDRYCB100, PDRYCB300, PDRYCB400
Wind Baffle Kit
ZLABGP01A ZLABGP01A ZLABGP02A
Wi-Fi
2
Water Level Sensor Connection (for optional AG-9300-LG)
Drain Pan Heater
PQSH1201
Smart Inverter Monitoring System (SIMS)
√ = Standard feature
X = Not available
¹Function can operate only when a wired remote controller is connected.
2
Wi-Fi is only compatible with 2.4 GHz band, and cannot be used when dry contact mode is active. When changing from Wi-Fi mode to dry contact mode,
normal operation resumes in approximately 3 minutes.
LonWorks® is a trademark of Echelon Corporation ; BACnet® is a registered trademark of ASHRAE.