Do you have a question about the LG LS090HFV3 and is the answer not in the manual?
Brand | LG |
---|---|
Model | LS090HFV3 |
Category | Air Conditioner |
Language | English |
Indicates an imminently hazardous situation leading to death or serious injury if not avoided.
Indicates a potentially hazardous situation which could result in death or serious injury if not avoided.
Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided.
Indicates situations that may result in equipment or property damage accidents only.
Defines model series like Art Cool Premier/Gallery/Mirror and High Efficiency/Standard/Mega.
Denotes Indoor Wall Mount Unit (N) or Outdoor Heat Pump Unit (U).
Indicates nominal cooling capacity in Btu/h, e.g., 090 for 9,000 Btu/h.
Specifies product types like Mega (HEV), Standard Efficiency (HFV), Mega 115V (HXV).
Indicates the product's generation, e.g., 1 = First, 2 = Second.
Lists LATS HVAC, LATS CAD2, and LATS Revit formats, available via www.myLGHVAC.com.
Highlights LATS software features like ease of use, tree mode, schematic diagrams, and input options.
Details LATS report generation and the proper design to install procedure.
Describes the basic system configuration: single outdoor, single indoor, single circuit.
Specifies operating temperature ranges for cooling and heating for Mega and Mega 115V models.
Details the construction materials for outdoor and indoor units.
Outlines the refrigerant type (R410A) and main components like EEV and reversing valve.
Describes the hermetic, digitally controlled, inverter-driven twin-rotary compressor.
Covers power supply voltage and tolerance for HEV2/HFV3 and HXV2 models.
Lists factory-wired components and microprocessor-based algorithms for protection and control.
Shows available outdoor and indoor unit combinations with their controllers.
Provides electrical specifications for 208-230V systems in a table.
Lists electrical specifications for 115V systems in a table.
Lists indoor unit types, their functions, and controller compatibility.
Details remote controllers and optional function kits like Wi-Fi Module and SIMS.
Provides dimensional drawings and measurements for various outdoor unit models.
Shows dimensional drawings and measurements for various indoor unit models.
Explains measurement and presents acoustic data for indoor units.
Explains measurement and provides acoustic data for outdoor units.
Shows refrigerant flow diagram for HEV2/HFV3 models and lists thermistor details.
Shows refrigerant flow diagram for HXV2 models and lists thermistor details.
Provides wiring diagrams for indoor units (Mega/Standard and Mega 115V).
Shows wiring diagrams for outdoor units (Mega/Standard and Mega 115V).
Provides guidelines for power source, grounding, and cable specifications.
Illustrates power/communication schematics and terminal block wiring.
Details wired controller connections, placement, and notes.
Table showing air flow rate and static pressure for outdoor units.
Presents diagrams for air velocity and temperature distribution for indoor units.
Details the LGMV software and cable for diagnostics and data monitoring.
Describes the SIMS system for displaying and graphing operational data and troubleshooting.
Provides detailed cooling capacity tables for various models and conditions.
Offers detailed heating capacity tables for various models and conditions.
Lists maximum heating capacity tables for different models and conditions.
Guides on selecting equipment using correction factors and sizing checks.
Provides best practices and clearance requirements for indoor unit placement.
Details guidelines for selecting outdoor unit locations and planning for environmental factors.
Discusses reasons, benefits, design considerations, and guidelines for indoor installations.
Lists limitations, tables for pipe sizes, lengths, elevation, and refrigerant charge.