10. Ice Maker Motor Error (E It)
Symptom Check Point
1. E It 1. Check for a loose connection
2. Check Sensor Resistance
( P/N EBR809775**)
Housing Resistance [Ω]
CON6
7
th
pin ~ 8
th
pin
374~456
CON6
9
th
pin ~ 10
th
pin
374~456
CON6
57
CON 6
CON 5
CON 2CON 3
CON 8
CON 7
CON 201
CON 1
Copyright © 2017 LG Electronics Inc. All rights