14
ENGLISH
Y branch method
Combination of Y
branch/header Method
Header Method
:
Outdoor Unit
: 1st branch (Y branch)
: Indoor Units
: Outdoor Unit
: 1st branch (Y branch)
: Y branch
: Indoor Unit
: Header
: Sealed piping
: Outdoor Unit
: Header branch
: Indoor Units
: Sealed piping
: Outdoor Unit
: 1st branch (Y branch)
: Indoor Units
: Downward Indoor Unit
: Connection branch
pipe between
Outdoor units:
ARCNN31
: Connection branch
pipe between
Outdoor units:
ARCNN21
l
40 m (90 m : Conditional application)
h 30 m
H 90 m
L165 m
L 165 m
40 m(90 m : Conditional application)
H 90 m
30 m
L 165 m
40 m
H 90 m
30 m
1 Outdoor Units
Y branch method
Combination of Y branch/
header Method
H
eader Method
: Outdoor Unit
: Header branch
: Indoor Units
: Sealing
: Connection branch pipe
between Outdoor
units : ARCNN41
: Connection branch pipe
between Outdoor
units : ARCNN31
: Connection branch pipe
between Outdoor
units : ARCNN21
: Outdoor Unit
: 1st branch(Y branch)
: Y branch
: Indoor Unit
: Connection branch pipe
between Outdoor
units : ARCNN41
: Connection branch pipe
between Outdoor
units : ARCNN31
: Connection branch pipe
between Outdoor
units : ARCNN21
: Header
: Sealing
10 m or
less
L165 m
l 40 m (90 m : Conditional application)
H 90 m
Slave2
Slave3
Slave1
Master
G
ODU Capacity
Master ≥ Slave1 ≥ Slave 2 ≥ Slave 3
h 30 m
h1
10 m or
less
H 90 m
GG
FF
EE
G
F
E
L 165 m
l 40 m(90 m : Conditional application)
ODU Capacity
Master ≥ Slave1 ≥ Slave2 ≥ Slave3
30 m
Master
Slave3
Slave1
Slave2
h1
10 m or
less
H 90 m
L 165 m
40 m
M
aster
Slave3
Slave1
Slave2
ODU Capacity
Master ≥ Slave1 ≥ Slave2 ≥ Slave3
30 m
G
GG
h1
F
F
E
E
F
E
h See Table 2
A : Refrigerant pipe diameter from outdoor unit to first branch
E : Refrigerant pipe diameter for outdoor unit capacity
(Slave 1+ Slave 2+ Slave 3)
F : Refrigerant pipe diameter for outdoor unit capacity
(Slave 2+ Slave 3)
G : Refrigerant pipe diameter for outdoor unit capacity(Slave 3)
h * : See Table 4
L1
L2
L
3
h
1
E GF
S
lave3
S
lave2
Slave1
Master
l
40 m
h 30 m
I
ndoor
Unit
1
st branch
Refrigerant pipe diameter from outdoor unit to first branch
Level Difference
(Outdoor unit
Outdoor unit)
5m
Max length from first branch to
each outdoor unit (L1, L2, L3)
Less than 10 m
(equivalent length of piping 13 m)
Y branch
Method
Combination of Y
branch/header
Method
Header
Method
Max pipe
length
Outdoor Unit
Indoor Unit
Longest
pipe
length(L)
A+B+C+D+e165 m
A+B+b165 m
A+C+e165 m
A+f165 m
Equivalent
pipe length
190 m 190 m 190 m
Total pipe
length
1,000 m
1,000 m
1,000 m
Max
difference
in height
Outdoor Unit
Indoor Unit
Difference in
height(H)
90 m 90 m 90 m
Indoor Unit
Indoor Unit
Difference in
height(h)
30 m 30 m 30 m
Longest pipe
length after
1st branch
Pipe
length(l)
40 m
(90 m: Conditional
application)*
40 m
(90 m: Conditional ap-
plication)*
40 m
(Table 1) Limit Pipe length
Pipe Connection Method between outdoor
unit/indoor unit
Series Outdoor Units (2 Units ~ 4 Units)
Refrigerant piping system

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG MULTI V IV PRO ARUN220LLN4 and is the answer not in the manual?

LG MULTI V IV PRO ARUN220LLN4 Specifications

General IconGeneral
BrandLG
ModelMULTI V IV PRO ARUN220LLN4
CategoryAir Conditioner
LanguageEnglish

Related product manuals