- 23 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Features
Temperature range setting
• Function Code 13 : Setting air temperature in heating mode
Determine heating setting temperature range when air temperature is selected as setting temperature.
Only available when remote air temperature sensor is connected
• Accessory PQRSTA0 should be installed.
• Also, Function Code 03 should be set properly.
• Function Code 14 : Setting leaving water temperature in heating mode
Determine heating setting temperature range when leaving water temperature is selected as setting temperature.
• Function Code 15 : Setting sanitary tank leaving water temperature
Determine heating setting temperature range of water tank leaving water.
Only available when sanitary water tank feature is installed
• Sanitary water tank and sanitary water tank kit should be installed.
• DIP switch No. 2 and 3 should be set properly.
• Function Code 18 : Screed drying mode.
After installing water pipes for under floor heating, user can select screed drying mode for curing the cement.
- Value #1 : “01” Screed drying mode operating
“00” Screed drying mode is not operating.
- Value #2 : not used.