LG Therma V AHBW A0 Series - Concept of ʻClassified Troubleʼ; Self-Diagnosis Feature

LG Therma V AHBW A0 Series
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Self-Diagnosis Feature
- 46 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2. Self-Diagnosis Feature
2.1 Concept of ʻClassified Troubleʼ
• Definition of terms
- Trouble : a problem which can stop system operation, and can be resumed temporarily under limited operation
without certificated professionalʼs assist.
- Error : a problem which can stop system operation, and can be resumed ONLY after certificated professionalʼs
check.
- Emergency mode : temporary heating operation while system met Trouble
• Objective of introducing ʻTroubleʼ
- Not like airconditioning product, Air-to-Water heat pump is generally operating in whole winter season without
any system stopping.
- If system found some problem, which is not critical to system operating for yielding heating energy, the system
can temporarily continue operating in emergency mode with enduserʼs decision.
• Classified trouble
- Trouble is classified two levels according to the seriousness of the problem : Slight trouble and heavy trouble
- Slight trouble : In most case, this trouble is concerned with sensor problems. The outdoor unit is operating
under emergency mode operation condition which is configured by DIP switch No. 4 of the Main
PCB Assembly 1.
- Heavy trouble : As the outdoor unit has problem, the emergency mode operation is performed by electric
heater.
- Option trouble : a problem is found for option operation such as water tank heating. In this trouble, the troubled
option is assumed as if it is not installed at the system.
• Emergency operation is not automatically restarted after main electricity power is
reset.
- In normal condition, the product operating information is restored and automatically restarted after main electric-
ity power is reset.
- But in emergency operation, automatic re-start is prohibited to protect the product.
- Therefore, user must restart the product after power reset when emergency operation has been running.