EasyManua.ls Logo

LG Therma V AHBW A0 Series - Page 60

LG Therma V AHBW A0 Series
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trouble Shooting Guide
- 60 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Is the wire connection
normal ?
Is the SVC Valve
opened ?
Check the leakage of
refrigerant.
Check Pressure of
suction pipe
Check Pressure of
discharge pipe
Is the soldering
state of connector is
normal?
Yes
Yes
No
Correct connection
No
Re-soldering component
Yes
No
Open SVC Valve
Is it normal ?
Change main PCB 2
Yes
No
Re-vaccuming system
and Re-charging
Check Flow Chart
CN_PRESS
24
Press S/W Open
• Low / High pressure
S/W open.
• Check the connection of “CN_PRESS”
• Check the SVC V/V open.
• Check the leakage of refrigerant.
Display
code
Title Cause of error Check point & Normal condition