General Information
Description
Indoor unit(Internal)
474
848
305
66
39
75.11008176
109
52
474
No Name Remarks
1 Refrigerant Pipe Ø15.88mm(5~16kW), Ø12.7mm (3kW)
2 Refrigerant Pipe Ø9.52mm(5~16kW), Ø6.35mm (3kW)
3 Entering Water Pipe Male PT 1 inch
4 Leaving Water Pipe Male PT 1 inch
5 Control Panel Built-in Remote Controller
6 Water Pump Max Head 9 / 7 / 6 m
7 Safety Valve Open at water pressure 3 bar
8
8'
T
Thermal switch
hermal switch
Cut-off power input to electric heater at 90 °C (manual return at 55C)
(1Ø Electric Heater is applied)
Cut-off power input to electric heater at 90 °C (manual return at 55 C)
(3Ø Electric Heater is applied)
9 Control Box PCB and terminal blocks
Minimum operation range at 12 LPM.(5~9kW)
Minimum operation range at 15 LPM.(12~16kW)
※ 3kW IDU has not a flow switch.
11 Plate Heat Exchanger Heat exchange between refrigerant and water
12 Pressure Gage Indicates circulating water pressure
13 Expansion Tank Absorbing Volume change of heated water
14 Air Vent Air purging when Charging water
15 Electric Heater
Please refer to the below Page
‘Model name and related information’
16
17
Strainer
Shut-off valve
18
Carrying handle
Filtering and stacking particles inside circulating water
To drain or to block water when pipe connecting
To carry the product
Flow Switch10
(unit:mm)
22 Air-to-Water Heat Pump