VALVE (STEAM)
VALVE (
PRE-WASH)
VALVE
(NORMAL-WASH)
1
Disconnect the wiring connector.
1
1
2
3
2
Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5k
2
When reconnecting the connector
1
Open the door completely.
2
Remove the two screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
Drain from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
INLET VALVE
3
DOOR
Removing method of remaining water
CAP(REMAING HOSE)