2) Disassembly of Back Panel, Power
Cord, Inlet Valve and BP Sensor
① Remove two back panel fixing screws in the back
side.
② Disassemble the back panel.
③ Disconnect two connectors and disassemble the
power cord.
④ Remove a valve fixing screw and disconnect the leads
from the inlet valve.
For connecting the leads of inlet valve, keep
the following. (Location and Color)
⑤ Remove the inlet valve.
⑥ Disconnect the leads and the pressure tube from
the pressure sensor.
⑦ Remove the pressure sensor.
RED
BLUE
WHITE
Hinge Pin Hinge Pin
Pressure sensor
Power cord
Inlet valve
Back Panel
Q-spring