Examples:
AO-7 and 8 = 0 - 0 ENABLED IN T1 AND T2
The relaxation function is always enabled, independent of the state of the
INC/DEC signals.
AO-7 and 8 = 0 - 1 ENABLED IN T1
The relaxation function is only enabled in T1.
AO-7 and 8 = 1 - 0 ENABLED IN T2
The relaxation function is only enabled in T2.
AO-7 and 8 = 1 - 1 ENABLED VIA A DEDICATED PROCEDURE
The relaxation function operates in different ways as a function of the yarn
relaxation type:
Tension Relax
The relaxation function is only enabled following receipt of the dedicated
timed procedure.
After that, it is only run when the yarn feeding speed falls below the thresh-
old set in “SR-Speed Relax”, and the device switches to T2.
The function is inhibited when the yarn feeding speed is reinstated or the
device switches to T1.
Wheel Turn Relax (special functions F1 and F2 in parameter
“SR- Speed Relax”).
The relax function is only enabled following receipt of the dedicated timed
procedure.
After that, it is run in T1 and T2, only when the yarn feeding speed falls to 0.
The function is inhibited when the device receives increases or
decreases.
4.2.10 “Yarn Rigid. (Yarn Rigidity)
In this menu, you can set the yarn tension as a function of rigidity of the yarn
being used.
4 - SETTING THE OPERATING PARAMETERS
Use + or - to set the
desired value
Scroll the parameters by
using + or -