For elastic yarns, a low “YR” value must be set, whereas for rigid yarns a
high “YR” value is required.
This value can be set from 1 to 5. The default setting is 1.
By holding pressed the “X” button for 3 seconds, the minimum value that the
parameter can take is set.
4.2.11 “Brake Rate”
In this menu the Braking Rate can be selected.
The default setting is 1.
By holding pressed the “X” button for 3 seconds, the minimum value that the
parameter can take is set.
4.2.12 “Offset Calib” (Cell Offset Calibration)
N.b.: for the Cell Offset Calibration procedure, see also paragraph 3.1.
WARNING!!! Prior to threading, ensure that the accumulator
is temperature-stabilised with its surroundings.
We suggest you wind the wire 15 minutes after power-on, provided
that the Offset Calibration has been performed.
4 - SETTING THE OPERATING PARAMETERS
Use + or - to set the
desired value
Scroll the parameters by
using + or -
Coated elastic yarn 1
Plain elastomer 2
Rigid yarn 3 to 5 as a function of yarn rigidity
Minimum Breaking 0
Medium Braking 1
Maximum Braking 2