4.3 Fault status (alarm code)
In error alarm status, the alarm code ashes once every second on the displays ECU and PCU.
Table: alarm code
Chapter 4 - Operation
Display
01
02
03
12
18
31
32
42
43
46
47
52
53
54
55
56
57
58
60
61
62
63
64
65
66
67
68
70
71
72
73
74
75
76
77
78
79
80
81
82
83
89
90
91
92
99
0L
LL
Machine response
Stop all actions
Stop all actions
Stop all actions
Stop all chassis controllers
Stop lifting and moving
Stop all actions
Stop all actions
Show alarm only
Show alarm only
Stop platform control
The speed is reduced to the lifting speed
Stop lifting and moving
Stop lifting and moving
Stop lifting and moving
Stop lifting and moving
Stop lifting and moving
Stop lifting and moving
Stop lifting and moving
Warning, unable to walk and lift
Warning
Warning
Warning
Warning
Stop all actions
Warning, unable to walk and lift
Warning, unable to walk and lift
Warning
Warning
Warning, unable to walk and lift
Warning, unable to walk and lift
Warning
Warning, unable to walk and lift
Alarm only
Warning, unable to walk and lift
Warning, unable to walk and lift
Warning, unable to walk and lift
Warning, unable to walk and lift
Alarm only
Warning, unable to walk and lift
Warning, unable to walk and lift
Alarm only
Stop all actions
Stop lifting and moving
Description
System initialisation error
System communication error
Invalid set up error option
Open error of lifting or lowering button on chassis in the start process
Error from hollow protector
Pressure sensor error
Angle sensor error
Press error of left turn button on the platform in the start process
Press error of right turn button on the platform in the start process
Press error of power button on the platform in the start process
Platform handle error not positioned in the center of the starting process
Forward coil error
Reverse coil error
Raising and lifting coil error
Increase and descend coil error
Right steering coil error
Left steering coil error
Brake coil error
(because the brake coil is optional, this function is temporarily tested)
Motor Controller Comprehensive Fault
Controller Current Sensor Fault
Controller Hardware or Software Failsafe Fault
Motor Controller Motor Output Fault
Motor Controller SRO Fault
Motor Controller Throttle Fault
Motor Controller Emergency Reverse Fault
Motor Controller HPD Fault
Low voltage alarm
Steering Input Out of Range (Only ZAPI)
Motor Controller Main contactor Fault
Motor Controller Over Voltage Fault
Motor Controller Analog Control Fault
Motor Controller Motor Fault
Pump Motor Fault
Left Drive Motor Fault
Warning, unable to walk and lift
Pump Motor Short or Pumping Speed Input Fault
Left drive Motor Short Fault
Alarm when exceeding 80% load
Right drive Motor Short Fault
Left Brake Coil Fault
Right Brake Coil Fault
Drive Motor Excitation Open Fault
Alarm when exceeding 90% load
Left drive Motor Excitation Open Fault
Right drive Motor Excitation Open Fault
Alarm when exceeding 99% load
Platform overload alarm
Machine ramp error exceeding safety limit