Chapter 1 - Safety
1.7 Electrocution Risk
1) The machine is not insulated so that there is no electrical shock protection when touching or coming close to
an electricity cable. Keep distance from the electricity cable and the power supply according to the laws and
regulations and description in the table below.
2) Consider the inuence of moving on the platform and turning and relaxing the electricity cable in strong winds
or gusts of wind.
3) Stay away from the machine if it comes into contact with a live electricity cable.
Do not touch the machine or the operated machine on the ground or on the platform, to disconnect the power
supply.
4) Do not use the machine during thunderstorms or rainstorms.
5) Do not use the machine as a ground wire during welding.
6) Do not touch the charger while charging.
1.8 Tilt Risk
The personnel, equipment and material on the platform must not exceed the maximum bearing capacity of the
platform and the extended platform.
type indoor use outdoor use
max workload
max platform workload
SS0407E 2 Persons 1 person 240 Kg 113 Kg
SS0507E 2 Persons 1 person 230 Kg 113 Kg
SS0607E/AS0808/AS0808E 2 Persons 230 Kg 113 Kg
AS0607/AS0607E 2 Persons 230 Kg 120 Kg
AS0607W/AS0607WE 2 Persons 1 person 380 Kg 120 Kg
AS0608/AS0608E 2 Persons 1 person 380 Kg 113 Kg
AS0812/AS0812E 2 Persons 1 person 450 Kg 113 Kg
AS1012/AS1012E 2 Persons 1 person 320 Kg 113 Kg
AS1212/AS1212E 2 Persons 320 Kg 113 Kg
AS1413 2 Persons 200 Kg 113 Kg
Tension
0-300V
300V-50KV
50KV-200KV
200KV-350KV
350KV-500KV
500KV-750KV
750KV-1000KV
Required space
Do not touch
3,05m
4,6m
6,10m
7,62m
10,67m
13,72m